Adaptica – Binocular Mobile Autorefractor and Vision Analyzer – 2WIN

The Adaptica 2WIN is a binocular mobile refractometer and vision analyzer that performs binocular refraction in real life vision conditions in order to objectively assess refraction, binocular alignment, opacities, pupillometry, and angle kappa. The 2WIN is extremely fast and will significantly enhance office efficiency as it can perform vision screenings on a large number of people in a short period of time. The 2WIN is able to perform a binocular evaluation in less than 15 seconds.

Share :
binocular monocular refraction 2win adaptica - us phthalmic

Applications & Benefits of the 2WIN


The 2Win may be integrated with the Vision Fit Adaptive Optics Refraction System to provide the most advanced mobile refraction process available. This system is light, wireless, and easy to transport and set up for remote applications and screenings. The system can operate in small areas (refracting distance as short as 1 meter), enabling unlimited flexibility for providing objective and subjective refractive exams. The 2WIN allows for quick and accurate measurements of binocular refraction, and creates precise and objective measurements of ocular alignment, and can detect the major amblyogenic factors such as anisometropia, anisocoria, and media opacities. The 2WIN also has over-refraction capabilities for both spectacles and contact lenses and provides objective measurements of dynamic pupillometry.


binocular monocular refraction 2win adaptica - us phthalmic

Applications

Ophthalmic and Optometric Practices
Pediatric Eye Care
Orthoptics
Pediatricians
Vision Screening Programs
Mobile Eye Care
Occupational Medicine

binocular monocular refraction 2win adaptica - us phthalmic

Practice Applications

Rapid patient vision testing and screening
Refraction and vision analysis of infants (0-3 year)
Vision care of disabled and uncooperative patients
Analysis of binocular vision and accommodative balance
Early detection and documentation of multiple amblyogenic factors
Objective analysis of under or over corrections
Objective orthoptic exam

binocular monocular refraction 2win adaptica - us phthalmic

Eccentric Photo-Retinoscopy

The 2WIN measurement principle is eccentric photo-retinoscopy. Infrared (IR) light is projected through the patient’s pupils and onto the retina. Depending upon the refractive error, the reflected light forms a specific crescent-shaped brightness pattern within the pupil.

binocular monocular refraction 2win adaptica - us phthalmic
The 2WIN measures spherical power, cylinder power, and axis by interpreting the reflected light crescent pattern and position. The 2WIN infrared exam also provides valuable information about corneal abnormalities as well as ocular media opacities such as cataracts.

binocular monocular refraction 2win adaptica - us phthalmic

Binocular/ Monocular Refraction in a light controlled environment

When used with the Kaleidos module, the 2WIN can be used in a light controlled environment, eliminating distractions while fixing the distance for measurement. In this pairing, the instrument can be used for rapid walk-up screenings in any light conditions.

binocular monocular refraction 2win adaptica - us phthalmic

Extended Measurement Range

The 2WIN covers an impressive measurement range of spherical power from -15D to +15D.

binocular monocular refraction 2win adaptica - us phthalmic

Phorias and Tropias Early Detection

The 2WIN is capable of diagnosing myopia, hyperopia, astigmatism, and others. Additionally, it will provide evidence of sight anomalies that may be related to anisometropia, anisocoria, phorias, or strabismus.

binocular monocular refraction 2win adaptica - us phthalmic

Pupil Size Measurement

The 2WIN provides accurate and instant pupil size, pupil distance, and head tilt measurements.

binocular monocular refraction 2win adaptica - us phthalmic

Gaze Measurement

This package will add the feature to collect data from three measurements and will analyze the corneal reflex. The results will be expressed either in prism diopters or in degree.

binocular monocular refraction 2win adaptica - us phthalmic

Fully Automated and Easy to Use

The 2WIN works as a camera and operates at three feet (1 meter) distance. It needs only 3 seconds to get a complete screening of the patient. It then immediately provides a detailed PDF report to print and share.

binocular monocular refraction 2win adaptica - us phthalmic

Screening Report

With the 2Win, the customer can complete an objective assessment of the visual function in natural vision conditions. It is ideal for infants, children, the handicapped, and non-cooperative patients, due to the 2WIN’s small footprint and reduced exam time.

binocular monocular refraction 2win adaptica - us phthalmic

Connect to IR Printer

2WIN measurements can be printed and stored internally on a micro-SD card using a PDF format, which is capable of storing 1,000+ results.

binocular monocular refraction 2win adaptica - us phthalmic

WIFI

The 2WIN’s built-in WiFi connects seamlessly to the internet, making it possible to share results and diagnostics via email. The 2WIN also utilizes its WiFi capability to connect directly to the VisionFit.

binocular monocular refraction 2win adaptica - us phthalmic

Refract patients of all ages

The 2WIN can be used for patients as young as two months old and up to 120 years old.

Additional information

Operating Mode

Binocular / Monocular

Refraction Measurement

Automatic

Sphere Range

+15, -15 D, step 0.25 D

Cylinder Range

+5, -5 D, step 0.25 D

Cylinder Axis

1° – 180°, step 1°

Pupil Size

Automatic Detection, 0.15-0.27in, step 0.004in

Pupil Distance

Automatic Detection, 1.18-4.72in, step 0.04in

Fixation Target

Built-in

Acoustic Target

1 m ± 5 cm

Data Interface

Wi-Fi, USB, microSD card

Printer Interface

USB, Infrared (irda)

Power

Rechargeable Battery

Battery Charger

110-220 Vac, 0.5 A

Size

6.5 x 5.11 x 3.9 in

Display

3.5’’

Weight

1.85 lb

Options / Accessories

Portable wireless printer, supplementary battery, battery-charger, metal case, Wi-Fi connectivity

Brand

portable

Yes

Reviews

There are no reviews yet.

Be the first to review “Adaptica – Binocular Mobile Autorefractor and Vision Analyzer – 2WIN”

Your email address will not be published. Required fields are marked *

Your Review Your Review
Name Name

You may also like…

  • Adaptica Dynamic Pupillometry Application DP-App

    Adaptica – Dynamic Pupillometry Application – DP-App

  • Portable Printer for 2WIN

    Portable Printer for 2WIN

  • Adaptica Measurement of Tropias and Phorias Application CR-App

    Adaptica – Measurement of Tropias and Phorias Application – CR-App

  • Adaptica 2WINNY Mask Accessories for 2WIN

    Adaptica – Kit Masks & Stickers – 2WINNY MASKS

  • Adaptica Intermediate Distance 66cm-App

    Adaptica – Intermediate Distance – 66cm-App

  • Adaptica Binocular Visual Analyser Kaleidos

    Adaptica – Binocular Visual Analyzer – Kaleidos

  • Wireless Adaptive Refractor VisionFit Adaptica

    Adaptica – Mobile Wireless Adaptive Optics Refraction System – VISION FIT

  • Adaptica Lens Centering on Frames LC-App

    Adaptica – Lens Centering on Frames – LC-App